These experiments were conducted with secondary effluent from the terminal plant at Osaka, Japan, in order to determine the potential of the sponge ball cleaning system as an advanced reverse osmosis membrane cleaning technique. It was confirmed that sandfiltration of the feed as a method for reverse osmosis pretreatment and the use of chemical cleaning reagents to restore flux levels were unnecessary, when sponge ball cleaning was used. As a result, the product water flux was maintained at 0.65 ∼ 0.75m 3/m 2 day at 25°C and membrane rejection was more stable. No damage to the membrane, which would mean a decline of rejection ability, was recognized by scrubbing of the membrane surface by sponge rubber balls. It was confirmed that tight membranes were more suitable than loose ones because firstly it was easier to remove membrane fouling, secondly the product flux was nearly equal, and finally the product water was of better quality.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.