Abstract

A novel two-stage partial nitrification-anammox (PN-A) process was developed, achieving nitrogen removal from low carbon/nitrogen ratio municipal sewage under two typical operational modes and seasonal ambient temperatures. When complete nitritation-anammox was performed at temperatures greater than 19.4 °C, the effluent concentration of total inorganic nitrogen (TIN) was 4.1 mg/L, corresponding to a nitrogen removal efficiency (NRE) of 94.3 %. In contrast, when partial nitritation-anammox was performed at temperatures below 19.4 °C, the effluent TIN was 12.3 mg/L, corresponding to a NRE of 83.6 %. The relative abundance of Nitrosomonas and Nitrosomonadaceae increased from 0.02 % to 0.28 %, while Ca. Brocadia decreased from 1.85 % to 1.30 %, with the contribution of anammox to nitrogen removal being highest under low temperatures (19.4℃ to 13.8℃), at 59.0 %. This novel two-stage PN-A process provides a new approach for the stable operation of wastewater treatment plants (WWTPs) under low ambient temperatures.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call