Abstract

The prevalence of total knee arthroplasty (TKA) is increasing with the aging population. Although long-term results are satisfactory, suspected postoperative complications often require imaging with the implant in place. Advancements in computed tomography (CT), such as tin prefiltration, metal artifact reduction algorithms, dual-energy CT with virtual monoenergetic imaging postprocessing, and the application of cone-beam CT and photon-counting detector CT, allow a better depiction of the tissues adjacent to the metal. For magnetic resonance imaging (MRI), high bandwidth (BW) optimization, the combination of view angle tilting and high BW, as well as multispectral imaging techniques with multiacquisition variable-resonance image combination or slice encoding metal artifact correction, have significantly improved imaging around metal implants, turning MRI into a useful clinical tool for patients with suspected TKA complications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.