Abstract

This article presents the main methods of implementing degassing control systems, which allow for a radical reduction in the likelihood of accidents and achieving the most effective production results. The article discusses measures to prevent explosive gas concentrations during degassing operations, proposes optimal diameters and distances between degassing wells. Additionally, parameters influencing the volume of pumped methane are identified. A technology for sealing underground wells to maintain methane gas concentration is proposed. A modern mobile degassing unit is presented for methane extraction followed by utilization for electricity generation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.