Abstract

It is important to determine the source of the exergy destruction of the system components and their relations with each other in order to increase the working performance of energy charging systems. In this paper, conventional/advanced exergy and exergo-economic analyses of an advanced adiabatic compressed air energy storage (AA-CAES) system with a power output of 10 MW were performed. The results show that the proposed system accounts for 44 % of the exergy destruction and 31 % of the exergy destruction cost avoidable while 10 % of investment cost is avoidable. These percentage values represent the improvement potential for the system. Conventional exergy analysis results show that three most effective system components in exergy destruction as wind turbine, regulator and heat exchanger-3, respectively, while this order changes as wind turbine, compressor-1 and turbine-2 in advanced exergy analysis. This difference is due to technological limitations. In summary, advanced exergy analysis provides the designer with a detailed path regarding the improvement potential and cost savings of the system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.