Abstract

To evaluate utility of advanced CT techniques including HighlY constrained back-projection and dual-energy CT for intra- and post-procedure hepatic microwave ablation zone monitoring. 8 hepatic microwave ablations were performed in 4 adult swine (5min/65W). Low-dose routine CECT and dual-energy CT images were obtained every 1min during ablation. Images were reconstructed ± HYPR. Image quality and dose metrics were collected. 21 MWA were performed in 4 adult swine. Immediate post-procedure CECT was performed in the arterial, portal venous, and delayed phases using both routine and DECT imaging with full-dose weight-based IV contrast dosing. An additional 16 MWA were subsequently performed in 2 adult swine. Immediate post-procedure CT was performed with half-dose IV contrast using routine and DECT. 12 patients (10M/2F, mean age 62.4 yrs) with 14 hepatic tumors (4 HCC, 10 metastatic lesions) treated with MWA were prospectively imaged with DECT 1month post-procedure. 120kV equivalent images were compared to DECT [51keV, iodine material density]. Image quality and dose metrics were collected. Gas created during MWA led to high CNR in all intraprocedural CT datasets. Optimal CNRs were noted at 4min with CNR 6.7, 15.5,15.9, and 21.5 on LD-CECT, LD-CECT + HYPR, DECT, and DECT + HYPR, respectively (p < 0.001). Image quality scores at 4min were 1.8, 2.8, 2.4, and 3, respectively (p < 0.001). Mean radiation dose (CTDIvol) was eightfold higher for the DECT series. For swine, post-procedural DECT images (IMD/51keV) showed improved CNR compared to routine CT at all time points with full and with reduced dose contrast (CNR 4.6, 3.2, and 1.5, respectively, at half-contrast dose, p < 0.001). For human subjects, the 51keV and IMD images showed higher CNRs (5.8, 4.8 vs 4.0, p < 0.001) and SNRs (3.7, 5.9 vs 2.8). Ablation zone sharpness was improved with DECT (routine 3.0 ± 0.7, DECT 3.5 ± 0.5). Diagnostic confidence was higher with DECT (routine 2.3 ± 0.9, DECT 2.6 ± 0.8). Mean DLP for DECT was 905.7 ± 606mGy-cm, CTDIvol 37.5 ± 21.2mGy, and effective dose 13.6 ± 9.1mSv, slightly higher than conventional CT series. Advanced CT techniques can improve CT image quality in peri-procedural hepatic microwave ablation zone evaluation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call