Abstract

An improved control scheme for delta-connected cascade multilevel static synchronous compensator (STATCOM) operating under unbalanced conditions is proposed. The individual phase instantaneous current control is suitable for delta-connected cascade multilevel STATCOM which can be equivalent to three single-phase inverters. To compensate the system imbalance, the reactive control mode and the voltage control mode are studied, and the discrete current loop controller has been designed. Accordingly, the cascade multilevel STATCOM can maintain normal operation under unbalanced voltage by using the individual phase instantaneous current control strategy while the unbalanced system can be effectively compensated by the two modified compensation modes. The proposed control scheme has been verified by simulation and experimental results based on a three-phase 36-chain cascade multilevel STATCOM laboratory prototype are shown.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.