Abstract

Deformation of microporous activated carbon adsorbent ACC (adsorbent on the basis of silicon carbide) upon CO 2 adsorption has been studied. To solve this problem, a dilatometer was used. Its main part was a line differential transformer, the core of which was connected to the adsorbent by means of a rod. Any changes in the adsorbent height caused a change in the core position in the transformer, which influenced the signal recorded from its secondary winding. These results were compared with the adsorption isotherms. High sensitivity of the dilatometric method has been shown. The dilatometer used allowed the measurement of absolute deformation in the range 1×10 −4 to 3 mm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.