Abstract

In this work, it was found that exposure of barium carbonate to carbon dioxide (0.003%–5%) as active gas in wet synthetic air as carrier gas leads to an increase in work function between 50 and 150 meV at room temperature. Other carbonates show a similar behaviour and lower sensitivities. Without humidity in the carrier gas, the sensitivity of barium carbonate disappears. Measurements were performed on pressed pellets, thick films (10–100 μm) and thin films (1–2 μm) of the material using a Kelvin probe with gold grid as reference electrode. The effect was found to be independent of preparation. Between 23°C and 100°C, maximum sensitivity is reached at about 50°C. The work function change is attributed to the formation of dimeric HCO 3 − species which have been identified using diffuse reflectance infrared fourier transform (DRIFT) spectroscopy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.