Abstract

IntroductionThe coronary artery disease-reporting and data system (CAD-RADS) was developed to standardize communication of per-patient maximal stenosis and provide treatment recommendations that may affect downstream testing.MethodsDownstream testing, cardiology referral, and cost were abstracted for 1,796 consecutive patients undergoing coronary CT angiography (CCTA) before and after the adoption of the CAD-RADS reporting template at a single-center closed referral hospital system. Cost analysis was based on direct invasive and non-invasive testing utilizing the Center for Medicare & Medicaid Services (CMS) outpatient prospective payment system (OPPS) final rule for 2018.ResultsBaseline cardiovascular risk factors were balanced between the groups. Overall, referrals for downstream testing were similar between cohorts (10.7% vs 10.8%; p = 0.939). Referral for downstream testing was reduced in the CAD-RADS 1 & 2 cohort compared to non-obstructive coronary artery disease (CAD) by non-standardized reporting (NSR; 5.1% vs 14.4%, p < 0.001). This was offset by more non-diagnostic scans in the CAD-RADS cohort (9.7% vs 4.2%, p < 0.001), resulting in increased downstream testing (28.8% vs 11.4%, p = 0.038). Overall, cardiology referral rates by primary care providers (PCPs) were similar between the groups (12.2% vs 15.8%, p = 0.197). Cardiology referral rates were increased among patients with non-obstructive CAD in the NSR cohort compared with CAD-RADS 1 & 2 patients (20.5% vs 8.6%, p = 0.021). Referrals for invasive coronary angiography were low in both groups overall (3.5% vs 3.2%, p = 0.726). Median downstream testing costs were similar between the groups (p = 0.554).ConclusionsAdoption of the CAD-RADS reporting template was associated with a reduction in downstream testing and cardiology referral rates among non-obstructive CAD (CAD-RADS 1 & 2) patients. Thus, CAD-RADS may impact downstream testing in patients in whom further testing can typically be deferred.

Highlights

  • The coronary artery disease-reporting and data system (CAD-RADS) was developed to standardize communication of per-patient maximal stenosis and provide treatment recommendations that may affect downstream testing

  • Referral for downstream testing was reduced in the CAD-RADS 1 & 2 cohort compared to non-obstructive coronary artery disease (CAD) by non-standardized reporting (NSR; 5.1% vs 14.4%, p < 0.001)

  • This was offset by more non-diagnostic scans in the CAD-RADS cohort (9.7% vs 4.2%, p < 0.001), resulting in increased downstream testing (28.8% vs 11.4%, p = 0.038)

Read more

Summary

Methods

Downstream testing, cardiology referral, and cost were abstracted for 1,796 consecutive patients undergoing coronary CT angiography (CCTA) before and after the adoption of the CAD-RADS reporting template at a single-center closed referral hospital system. CCTAs over a 12-month period prior to local CAD-RADS adoption were included in the non-standardized reporting (NSR) cohort. CCTAs performed in the 12 months following CAD-RADS adoption were included in the. 2019 Boster et al Cureus 11(9): e5708. A two-month window was excluded between the two cohorts to account for variable rates of adoption among imaging providers. Hypertension was defined as a diagnosis of hypertension or utilization of an antihypertensive medication prior to CCTA. The medical specialty of the ordering provider was abstracted, along with the rate of downstream testing and cardiology referrals following CCTA

Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.