We present the study of electricity generation by utilization of the Kalina cycle system (KCS) as a bottoming cycle in the Wayang Windu geothermal power plant. The KCS converts the thermal energy from the waste brine discharged to the earth crust as a heat source. Based on the brine temperature condition, KCS 11 is the most suitable system among others owing to excellent performance at low to mid-regime temperatures. The constraints of the investigation are focused on the consideration of minimum silica saturation index (SSI) standard of the brine, owing to high SiO2 content. The system is optimized based on the most optimum ammonia-water mass ratio of the working fluid. The system can generate 1660.30 kW of electricity from 48 kg/s of unused brine with 13.20% thermal efficiency while maintaining the proper SSI standard. Owing to the nearly zero cost of heat production from the brine, this system can support the electrification of Wayang Windu geothermal power plant.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.