To evaluate the role of the Simple Rules (SR) from the International Ovarian Tumor Analysis group in contrast-enhanced ultrasound (CEUS) of for the differential diagnosis of benign and malignant adnexal tumors. A total of 180 patients with suspected malignant adnexal masses admitted to Lanzhou University Second Hospital were included, all of whom received conventional ultrasound (US) and CEUS examination before surgery. All masses were assessed using SR in US and SR in CEUS. To compare the diagnostic performance, the sensitivity, specificity, negative and positive predictive values, Youden index, and area under the curves values of SR in US and SR in CEUS were obtained. Sensitivity, negative predictive values, Youden index, and area under the curves were better for SR in CEUS than SR in US. The specificity and negative predictive value of SR in CEUS were lower than that of SR in US. Compared with SR in US, SR in CEUS significantly reduced the number of uncertain masses (21, 36.7% vs. 66, 11.7%). We concluded that SR in CEUS performed well in the diagnosis of malignant adnexal masses. SR in CEUS is a supplement to SR in US.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Gynecology & Obstetrics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.