Abstract

von Willebrand factor (VWF) plays an important role in the regulation of hemostasis and thrombosis formation, particularly under a high shear rate. However, the adhesive force due to the molecular interaction between VWF and glycoprotein Ibα (GPIbα) has not been fully explored. Thus, we employed atomic force microscopy to directly measure the adhesive force between VWF and GPIbα. We measured the adhesive force between VWF and GPIbα at the molecular level using an atomic force microscope (AFM). An AFM cantilever was coated with recombinant N-terminus VWF binding site of GPIbα, whereas a cover glass was coated with native VWF. The adhesive force at the molecular level was measured using an AFM. In the presence of 1 μg/mL VWF, the adhesion force was nearly 200 pN. As per the Gaussian fit analysis, the adhesive force of a single bond could have been 54 or 107 pN. Our consideration with the Gaussian fit analysis proposed that the adhesive force of a single bond could be 54 pN, which is very close to that obtained by optical tweezers (50 pN).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.