Adhesion strength of polyimide/Cr interfaces was measured using T-peel test on polyimide/Cr/Cu structures fabricated on BPDA-PDA polyimide, and correlation between adhesion strength and peeling angle has been investigated. Adhesion strength of BPDA-PDA/Cr interface decreased with increasing the thickness of Cr/Cu metal films to a critical value, and then increased with further increasing metal film thickness. When the thickness of Cr/Cu metal films was below a critical value, plastic bending of metal films mainly occurred during T-peel test. With metal films thicker than a critical thickness, however, plastic bending of polyimide film has been observed. A critical thickness of metal film, where transition from metal bending to polyimide bending occured, became thinner with decreasing the yield strength of metal film and increasing thickness of polyimide substrate. Without depending on the plastic bending of metal film or polyimide substrate, adhesion strength increased with increasing the peeling angle during T-peel test.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.