Abstract

In this work, the lack of adhesion occurred during the up-scaling of the deposition of tribological coatings in a semi-industrial apparatus is interpreted. The adhesion problems were detected for both hard and self-lubricant coatings from W–Ti–N and W:C systems, respectively, when they were deposited in a 4 cathodes TEER ® chamber by reactive unbalanced magnetron sputtering. In spite of cleaning the substrates surface by ion bombardment prior to deposition, by establishing a discharge close to the substrate, insufficient adhesion critical load values were measured by scratch-testing. A powerful set of complementary techniques was used to the detailed analysis of the interfaces in order to understand and overcome the adhesion problems: RBS gave some insights on the nature of the problem by detecting composition anomalies in the substrate/coating interface; Auger spectroscopy was used for identifying the underneath chemical composition close to the interface; cross section TEM gave the final evidence of the presence of a contamination layer attributed to malfunctioning of the ion cleaning process, which was the cause of the lack of adhesion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.