Abstract

Rotational angiography with digital three-dimensional reconstruction (3DRA) allows per-procedural 3D imaging to facilitate cardiac ablation procedures. We developed a new approach that allows per-procedural 3D imaging of the atria and ventricles with a single C-arm rotation, combining higher 3D image quality with a lower contrast and radiation dose. Forty patients underwent 3DRA of the left atrium (LA, n = 26), right atrium (RA, n = 11), left ventricle (LV, n = 2), or right ventricle (RV, n = 1) during ablation procedures performed under general anaesthesia. Contrast agent (60 +/- 12 mL) was diluted and injected directly in the chamber of interest, during adenosine-induced ventricular asystole (n = 31) or rapid RV pacing (n = 9, atrial imaging only) to reduce cardiac motion artefacts and enhance contrast opacification during rotational imaging. Reconstructed 3D data sets were graded according to predefined quality criteria (n = 40) and quantitatively compared with cardiac computed tomography (CT) (LA, n = 14). Adenosine-induced ventricular asystole and rapid pacing both allowed a sustained and homogeneous contrast opacification of target cardiac chambers, resulting in useful 3D data sets in 39 of 40 (98%) patients. Moreover, it was possible to achieve 'good' or 'optimal' 3D image quality in the majority of patients (adenosine: 61%, pacing 78%, P = 0.69). When compared with rapid pacing, the total elimination of cardiac motion artefacts with adenosine more frequently resulted in 'optimal' 3D image quality (42% vs. 11%, P = 0.01) and added the possibility for single-rotation 3D imaging of the ventricles. Quantitative analysis showed an excellent agreement between pulmonary vein diameters measured on cardiac CT and 3DRA images. Integration of 3DRA-based LA surfaces with real-time fluoroscopy was easy and highly accurate. Adenosine-induced ventricular asystole or rapid ventricular pacing allow acquisition of 3DRA with an excellent direct contrast opacification of any cardiac chamber and a reduction of cardiac motion artefacts, resulting in high-quality per-procedural 3D imaging with a single C-arm rotation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.