Abstract

This enzyme immunoassay detects adenosine deaminase binding protein (ABP), a glycoprotein that is shed from the brush border of the proximal tubule in kidney damage. Two monoclonal antibodies, URO-4 and URO-4a, each react with different epitopes on ABP and are used as the "sandwich" pair of antibodies. A linear standard curve can be generated by using partly purified ABP isolated from the urine of patients with kidney disease. Release of ABP into the urine appears to reflect the severity of the insult to the nephron. Therefore, measurement of ABP in urine may help distinguish between tubular disease and glomerular disease and indicate renal allograft rejection in renal-transplant patients.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.