Abstract
In this paper, direct torque and flux control of interior permanent magnet synchronous motor has been described in the stator flux field-oriented reference frame based on adaptive input-output feedback linearization (AIOFL) control method. The proposed control method does not need to know the motor two-axis inductances, the rotor permanent magnetic flux linkages, and the rotor position. However, the knowledge of the stator resistance is mandatory and that is estimated by AIOFL method. In practice, the rotor speed is approximately estimated by using the derivation of the stator flux vector angle in the stator stationary reference frame. The experimental and simulation results presented in this paper show the effectiveness and capability of the proposed control approach.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.