Abstract

BackgroundPatients treated with radiotherapy for head and neck (H&N) cancer often experience anatomical changes. The potential compromises to Planning Target Volume (PTV) coverage or Organ at Risk (OAR) sparing has prompted the use of adaptive radiotherapy (ART) for these patients. However, implementation of ART is time and resource intensive. This study seeks to define a clinical trigger for H&N re-plans based on spinal cord safety using kV Cone-Beam Computed Tomography (CBCT) verification imaging, in order to best balance clinical benefit with additional workload.MethodsThirty-one H&N patients treated with Volumetric Modulated Arc Therapy (VMAT) who had a rescan CT (rCT) during treatment were included in this study. Contour volume changes between the planning CT (pCT) and rCT were determined. The original treatment plan was calculated on the pCT, CBCT prior to the rCT, pCT deformed to the anatomy of the CBCT (dCT), and rCT (considered the gold standard). The dose to 0.1 cc (D0.1cc) spinal cord was evaluated from the Dose Volume Histograms (DVHs).ResultsThe median dose increase to D0.1cc between the pCT and rCT was 0.7 Gy (inter-quartile range 0.2–1.9 Gy, p < 0.05). No correlation was found between contour volume changes and the spinal cord dose increase. Three patients exhibited an increase of 7.0–7.2 Gy to D0.1cc, resulting in a re-plan; these patients were correctly identified using calculations on the CBCT/dCT.ConclusionsAn adaptive re-plan can be triggered using spinal cord doses calculated on the CBCT/dCT. Implementing this trigger can reduce patient appointments and radiation dose by eliminating up to 90% of additional un-necessary CT scans, reducing the workload for radiographers, physicists, dosimetrists, and clinicians.

Highlights

  • Patients treated with radiotherapy for head and neck (H&N) cancer often experience anatomical changes

  • The potential clinical impact of anatomical changes on the dose distribution for both the Planning Target Volume (PTV) and the Organ at Risk (OAR) has been explored in the literature

  • It is possible that the PTV coverage could be compromised [6], the maximum dose to the spinal cord could exceed tolerance, potentially resulting in paralysis, pain, and sensory deficits [7], and that sparing of other OARs could be ineffective, for example causing damage to the parotid glands leading to xerostomia [8]

Read more

Summary

Introduction

Patients treated with radiotherapy for head and neck (H&N) cancer often experience anatomical changes. The potential compromises to Planning Target Volume (PTV) coverage or Organ at Risk (OAR) sparing has prompted the use of adaptive radiotherapy (ART) for these patients. Intensity Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) have become the standard of care for patients receiving radiotherapy for cancer of the head and neck, due to the possibility of sculpting the dose distribution around the PTV and sparing the surrounding healthy tissues and organs at risk (OARs) [1,2,3]. It is possible that the PTV coverage could be compromised [6], the maximum dose to the spinal cord could exceed tolerance, potentially resulting in paralysis, pain, and sensory deficits [7], and that sparing of other OARs could be ineffective, for example causing damage to the parotid glands leading to xerostomia [8]. Modern conformal techniques continue to improve dosimetry and minimise negative clinical sequelae but there remains scope for improvement

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.