Abstract

This research paper is concerned with a successfully developed adaptive neuro-fuzzy inference system (ANFIS) for detection of indication size (of the penetrant) for liquid penetrant test. The evaluation of the neuro-fuzzy model has been comprehensive; it has been performed using a database of indication size containing 252 valid data points in a structural steel sample and 468 valid data points in high-alloy steel sample. The surface discontinuities are artificially drilled holes varying in diameter and depth from 0.5 to 1.75 mm, respectively, with an increment of 0.25 mm between each hole. The test is conducted at varying time intervals from 2 to 30 min for structural steel samples and 2 to 60 min for high-alloy steel samples, respectively, and the results are obtained till 1/100th of an mm. The ANFIS modelling accuracy is very high, with R² values reaching about 0.9924 for the test set when 83:17 ratios for train set:test set are taken. Use of this technique can be useful as this would help with the correct detection of discontinuities and in deciding whether to reject or accept a sample.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.