Abstract
The study presents a recursive least-squares estimation method with an exponential forgetting factor for noise removal in functional near-infrared spectroscopy data and extraction of hemodynamic responses (HRs) from the measured data. The HR is modeled as a linear regression form in which the expected HR, the first and second derivatives of the expected HR, a short-separation measurement data, three physiological noises, and the baseline drift are included as components in the regression vector. The proposed method is applied to left-motor-cortex experiments on the right thumb and little finger movements in five healthy male participants. The algorithm is evaluated with respect to its performance improvement in terms of contrast-to-noise ratio in comparison with Kalman filter, low-pass filtering, and independent component method. The experimental results show that the proposed model achieves reductions of 77% and 99% in terms of the number of channels exhibiting higher contrast-to-noise ratios in oxy-hemoglobin and deoxy-hemoglobin, respectively. The approach is robust in obtaining consistent HR data. The proposed method is applied for both offline and online noise removal.
Highlights
Functional near-infrared spectroscopy is a non-invasive optical brain imaging technique that measures oxy-hemoglobin (HbO) and deoxy-hemoglobin (HbR) concentrations in the brain [1]
A continuous wave Functional near-infrared spectroscopy (fNIRS) (CW-fNIRS) system detects a brain activity based on the intensity changes of the detected light while a constant intensity of the incident light is continuously exposed on the brain
The results indicated that contrast-to-noise ratio (CNR) of the proposed method exceeded those computed by the low-pass filtering (LPF) method in all channels
Summary
Functional near-infrared spectroscopy (fNIRS) is a non-invasive optical brain imaging technique that measures oxy-hemoglobin (HbO) and deoxy-hemoglobin (HbR) concentrations in the brain (or body) [1]. The intensity changes in the detected lights are utilized to compute the changes of HbO and HbR by using the modified Beer–Lambert law (MBLL) [1, 4,5,6,7,8,9]. The advantages of the fNIRS technique are non-invasive, inexpensive, quiet, harmless, and portable.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.