Abstract

An adaptive calibration method for three axial magnetic fluxgate sensor using support vector regression (SVR) is proposed in this paper. Firstly, the main problems arise from non-orthogonality, different sensitivity and bias of the three axes are analyzed. Then a relevant mathematic calibration model in matrix form is constructed to rectify these errors, and is converted to linear form one. Next, the coefficients of calibration model are identified by SVR algorithm. Practical measurement data of geomagnetic field are used to test, and the results show that the measurement errors of three axes fluxgate sensor in different attitude can be rectified under 50nT from 800nT.Because there is no need of any other auxiliary equipment, the proposed method seems to be a better candidate for fast or field calibration of three axial magnetic fluxgate sensors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.