Abstract

The evaluation of a commercial, belt-mountable “electronic nose” modified for the rapid recognition and quantification of individual solvent vapors and simple vapor mixtures at low ppm concentrations is described. Marketed under the name VaporLab® this direct-reading instrument was designed for qualitative determinations of the presence or absence of selected individual vapors and was adapted in this study for quantitative determinations of vapors and vapor-mixture components. Vapor samples are concentrated on a small adsorbent bed and then thermally desorbed for analysis by an array of four polymer-coated surface acoustic wave sensors. Tests were performed with 13 organic solvent vapors individually and in selected binary, ternary, and quaternary mixtures at concentrations ranging from 0.1 to 12 times the respective American Conference of Governmental Industrial Hygienists' (ACGIH®) threshold limit value (TLV®). Pattern recognition analyses yielded a library of response patterns to which subsequent actual and virtual (i.e., Monte-Carlo simulated) samples were compared to assess performance. Limits of detection < 0.025 × TLV are achieved (based on the most sensitive sensors) for 0.25 L of preconcentrated air samples collected over a 2-min period. Individual vapors from different functional group classes can be recognized, quantified, and discriminated from other vapors with little error, and discrimination of the components of binary mixtures is possible where the component vapor response patterns are sufficiently different. Within-class individual vapor and binary-mixture discriminations are more difficult and most ternary and higher-order mixtures could not be analyzed with acceptable accuracy. Changes in ambient humidity have no effect on responses and changes in temperature lead to well-behaved and compensable changes in responses. Tests of fluctuating concentrations demonstrate the capability for accurately tracking short-term variations in exposure. Overall, results suggest that this instrument could serve effectively as a personal exposure monitor in previously characterized occupational environments with proper revisions in design.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.