Abstract

Objectives We evaluated the results of acute application of the Ilizarov external fixator for segmental tibial fractures and also examined the experience with these special type fractures. Methods Twenty-four patients (19 males, 5 females) with a mean age of 37.8 years (range 22–66) with segmental tibial fractures were treated with the use of an Ilizarov type circular fixator. According to the categorisation of Melis et al., the fractures were types I, II, III and IV in seven, nine, five and three patients, respectively. Seven fractures were closed and 17 were open (9 grade IIIa, 5 grade IIIb, 2 grade II, 1 grade I according to the Gustilo classification). The mean time from the injury to surgery was 14 h (range 4–36). Eight patients with partial-thickness soft-tissue defects with no bone exposure were managed by split thickness skin grafting. Flap procedures were performed in four patients. All patients had good lower leg viability with a MESS score 6 and below. No patients had bone defects of 3 cm or more at the fracture level. Functional and bone results were made using the criteria proposed by ASAMI. The mean follow-up 28 months (range 12–70). Results We obtained excellent results in 20 and good results in 4 patients in terms of bone assessment. Functional results were excellent in 19 and good in 5 patients. All radiological evaluations showed normal alignment except in two patients. Both united with a residual procurvatum deformity. No rotational deformity was seen. Bone grafting was performed in one patient with a distal fracture. Complete union was achieved in all patients. None of the patients required amputation. There were no refractures after frame removal. Pin-tract infection occurred in 13 of the 24 patients. There were no incidents of chronic osteomyelitis secondary to pin-tract infection. The mean time for proximal fracture union was 36.4 weeks (range 10–78) and 39.8 weeks (range 12–80) for the distal fractures ( p > 0.05). Callus and consolidation occurred earlier posterolaterally. There were no implant failures. Conclusion Ilizarov external fixator is a successful method in the acute management of segmental tibial fractures. This method is particularly effective in the treatment of distal segmental fractures of the tibia when the distal segment is short. This method allows for control of complications by decreasing the need for new operations even in the presence of infection.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.