Abstract

PurposeTo compare the acute toxicities in radical treatment of prostate cancer between conventional schedule (C-ARM) with 78 Gy/39 fractions and hypofractionation conformal treatment (H-ARM) with 69 Gy/23 fractions.Methods and materialThis prospective double arm study consisted of 217 patients with prostate cancer, 112 in H-ARM and 105 in C-ARM arm. C-ARM received conventional six- field conformal radiotherapy with 78 Gy in 39 fractions while H-ARM received hypofractionation with 69 Gy in 23 fractions. Weekly assessment of acute reactions was done during treatment and with one, and 3 months using RTOG scale. Univariated analysis was performed to evaluate differences between the incidences of acute reaction in the treatment arms. Variables with p value less than 0.1 were included in the multivariated logistic regression.ResultsThere was no difference between H-ARM versus C-ARM for severity and incidence in genitourinary (GU) and gastrointestinal (GI) acute toxicity. During the treatment comparing H-ARM with C-ARM no differences was observed for GI toxicity (grade 0–3; H-ARM = 45.5%, 34%, 18.7% and 1.8% versus C-ARM = 47.6%, 35.2%, 17.2% and 0). For acute GU toxicity no difference was detected between H-ARM (grade 0–3; 22.3%, 54.5%, 18.7% and 4.5%) and C-ARM (grade 0–3; 25.8%, 53.3%, 17.1% and 3.8%).At the 3- months follow-up, persistent Grade > =2 acute GU and GI toxicity were 2.5% and 1.8% in H-ARM versus 5.7% and 3% in C-ARM (p > 0.05). In univariated and multivariated analyses, there was not any dosimetric predictor for GI and GU toxicity.ConclusionsOur data demonstrate that hypofractionated radiotherapy achieving high biological effective dose using conformal radiotherapy is feasible for prostate cancer, being well tolerated with minimal severe acute toxicity.

Highlights

  • In the last decades, it has been shown that exists a dose–response relation between the prostate cancer biochemical control and the total dose of radiotherapy delivered [1]

  • There was no difference between hypofractionation conformal treatment (H-ARM) versus C-ARM for severity and incidence in genitourinary (GU) and gastrointestinal (GI) acute toxicity

  • For acute GU toxicity no difference was detected between H-ARM and C-ARM

Read more

Summary

Methods and material

This prospective double arm study consisted of 217 patients with prostate cancer, 112 in H-ARM and 105 in C-ARM arm. Variables with p value less than 0.1 were included in the multivariated logistic regression

Results
Conclusions
Introduction
Material and methods
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.