Abstract
The purpose of this study was to assess the potential role of MR imaging with polylysine-Gd-DTPA enhancement in the early detection of acute occlusive intestinal ischemia in a rat model. After devascularization of the distal ileum in 12 rats, T2-weighted fast spin-echo MR images were acquired, followed by T1-weighted images before and after IV administration of 0.1 mmol/kg polylysine-Gd-DTPA. The signal intensity of the ischemic intestine did not differ significantly from that of the normal intestine before the administration of the contrast material. No mucosal or submucosal edema or hemorrhage was found in the ischemic intestine at histologic examination. After the administration of polylysine-Gd-DTPA, the ischemic intestine lacked enhancement and its signal intensity was significantly lower than that of the normal intestine. MR imaging with polylysine-Gd-DTPA enhancement can detect acute occlusive ischemia of the rat intestine at an early stage.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.