Abstract

ObjectivesTo assess the incidence of acute adverse events (AAEs) in gadolinium-enhanced cardiac magnetic resonance (CMR) imaging.MethodsGadolinium-based contrast agent (GBCA)–enhanced CMR data from the multinational, multicenter European Society of Cardiovascular Radiology MRCT Registry was included. AAE severity was classified according to the American College of Radiology Manual on Contrast Media (mild, moderate, severe). Multivariable generalized linear mixed effect models were used to assess the likelihood of AAEs in various GBCA, adjusting for pharmacological stressor, main indications (i.e., suspected or known coronary artery disease or myocarditis), age, sex, and submitting center as a random effect.ResultsIn the study population of 72,839 GBCA-enhanced CMRs, a total of 260 AAEs were reported (0.36%), with a minority of severe AAEs (n = 24, 0.033%). Allergic-like AAEs were less likely than physiologic AAEs (29% versus 71%). Patients without pharmacological stress imaging had a lower AAE rate (0.22%) compared to stress imaging (0.75%), with the highest AAE rates for regadenoson (2.95%). AAE rates also varied by GBCA subtype (overall p < 0.001). There was significant interaction between GBCA and pharmacological stressor (interaction p = 0.025), with AAE rates ranging between 0 and 10% for certain GBCA/stressor combinations. There was further marginal evidence that higher GBCA volume was associated with higher AAE incidence (OR = 1.02, p = 0.05).ConclusionGBCA-enhanced CMR imaging demonstrates low AAE rates comparable to those of other body regions. AAE likelihood correlates with GBCA subtype, pharmacological stressor, and imaging indication. Intravenous fluid administration in patients with cardiac impairment might contribute to these findings.Key Points• Acute adverse event rates in cardiac magnetic resonance (CMR) imaging with gadolinium-based contrast agents (GBCAs) are low (0.36%), especially for severe adverse events (0.033%).• Mild and moderate adverse events are more frequent during stress CMR imaging.• Physiologic AAEs are more common than allergic AAEs in CMR imaging.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.