Abstract

A dual resonant converter using active clamp circuit is presented in this paper. The active clamp circuit is employed to limit the voltage stress and create zero-voltage-switching (ZVS) turn-on feature for power switches. Moreover, the dual resonant tanks are composed by the leakage inductors and resonant capacitors to achieve zero-current-switching (ZCS) turn-off mechanism for diodes at the secondary side of transformer. Hence, the reverse-recovery problem can be eliminated. The operational principles, design consideration and realization are discussed. Finally, experimental results from a 400W prototype are presented to confirm the effectiveness of the proposed converter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.