Abstract
Recently, active vibration control has been applied to some bridges and buildings. However, the control has only been used to reduce vibration of lower modes. Control methods and spillover problems have also been discussed, but little has been done in terms of analysis of the number and location of actuators. For reduction of the vibration of higher modes, it is necessary to use many actuators. In terms of industrial application, it is important to know the necessary number and optimum location of actuators in order to obtain the required vibration reduction. In this report, we discuss the relationship between the number and location of actuators and vibration reduction for stationary vibration of a simple supported uniform beam. The following results were obtained. First, vibration reduction is strongly affected by the location of the actuators. Second, vibration reduction varies according to the distribution pattern of forces. Based on the findings, an estimation technique for the vibration reduction was proposed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.