Abstract

The 1.8-m primary mirror of solar telescope is heated by the solar radiation and introduce harmful mirror seeing degrading the imaging quality. For the Chinese Large Solar Telescope (CLST), the thermal requirement based on the quantitative evaluation on mirror seeing effect shows that the temperature rise on mirror surface should be within 1 kelvin. To meet the requirement, an active thermal control system design for the CLST primary mirror is proposed, and realized on the subscale prototype of the CLST. The experimental results show that the temperature on the mirror surface is well controlled. The average and maximum thermal controlled error are less than 0.3 and 0.7 kelvins respectively, which completely meets the requirements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.