Abstract
We have applied feedback control to the compressor of a 45kW auxiliary power unit. Using this, the engine is able to deliver more than 10% extra shaft power before surge occurs. We achieve control by suppressing a non-axisymmetric flow phenomenon in the diffuser of the centrifugal compressor. Control is effected by modulating a small extra air flow into the impeller. We present results of modelling and analysis which suggest that linear feedback control will be sufficient to stabilize a compression system, even when both axisymmetric surge and rotating stall are present as possible instabilities.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.