Abstract
Active fault detection consists of finding an auxiliary input signal such that its use allows detection of faults using a multi-model framework. Faults can be detected during a test period that would otherwise not be possible to detect during normal operation using passive tests. In this paper, we consider the problem of optimal exogenous signal design for a linear uncertain system controlled by a linear feedback. This signal design is based on controller design criteria of linear quadratic regulators (LQR). Optimal exogenous signal design for short test periods is considered first. An efficient method is developed to solve the corresponding finite time-horizon optimization problem. Then the asymptotic behavior of the robust fault detection problem and its stationary optimal solution is considered. The optimal exogenous signal for the stationary case is given based on a frequency analysis of the solution. This signal can be used as an approximation on longer interval finite time-horizons. It is shown that a suitable feedback can reduce the cost function compared with the open-loop case.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.