Abstract

Four voltage-controlled plasma electrolytic oxidation (PEO) coatings were developed on AA2024 aluminum alloy at 350V, 400V, 450V and 500V. Zn–Al LDH layer was in situ grown and loaded with corrosion inhibitor (vanadate) on the coatings to provide active protection to the PEO layers. The structure, morphology and composition of PEO coatings without and with LDH-NO3 and LDH-VOx were investigated using SEM, EDS, XRD and GDOES. Coatings formed at higher voltages (thicker and more stable) reveal a decrease of LDH flakes on the surface. The corrosion behavior and the effectiveness of LDH formation and inhibitor intercalation were also studied. Electrochemical impedance spectroscopy and scanning vibrating electrode techniques have shown a remarkable increase in the corrosion resistance of the LDH-inhibitor treated sample in comparison with PEO coated AA2024 specimen.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.