This paper presents an optimal total harmonic distortion (THD) control algorithm referred to as active harmonic elimination method for cascaded H-bridges multilevel converter control with unequal DC sources. First, the multilevel converter is decoupled into unipolar converters, the low order harmonics, such as the 5th, 7th, 11th and 13th are eliminated by using elimination theory, and the minimum THD combination of unipolar converters for multilevel converter control is found. Next, the magnitudes and phases of the residual higher harmonics are computed and subtracted from the original output voltage waveform to eliminate these higher harmonics. To validate the proposed algorithm, the method is simulated by Matlab first. After the simulation, an experimental 11-level H-bridge multilevel converter with a real-time controller based on Altera FLEX 10 K field programmable gate array (FPGA) is used to implement the algorithm with 8 /spl mu/s control resolution. The experimental results show that the method can effectively eliminate the specific harmonics as expected, and the output voltage waveforms have low THD.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.