Abstract
In recent year, improving server cooling efficiency has become an essential requirement in data centers. However, because the thermal dynamics of the server system has characteristics such as nonlinearity, significant inter-loop coupling, and continuously fast changing/unknown workload disturbances, this poses huge challenges to control engineers and data center architect engineers. To address the above concerns, this paper presents an active disturbance rejection control based decoupling control algorithm for flash storage systems and CPUs in a one-unit server to simultaneously improve fan power consumption efficiency and regulate the server components' temperature to avoid downgraded performance caused by overheating. In the study, a benchmark system is established based on the Samsung Mission Peak (MP) server where the thermal characteristics and existing solutions are both systematically evaluated. Performance of the design concept is proved in simulation. Experiment results show that, with the proposed control solution, temperature overshoot is greatly eliminated, temperatures are more tightly controlled and the drive throttling rate are greatly decreased. Furthermore, the proposed method is shown to be able to save up to 45% energy versus a PID controller, saves about 77% energy versus dynamic fan speed control method, and saves about 98% energy versus native fan speed control.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.