Abstract
Reversible high-pressure metal hydrides offer excellent cold start capability and potentially increased hydrogen storage capacity. However, efficient thermal management is a critical issue in this kind of systems. In the present work, hydriding and dehydriding tests have been conducted with 100 g of Ti 1.1MnCr metal hydride at pressures up to 330 bar. Thermal characteristics of the Ti 1.1MnCr system have been quantified from the experimental data and simulated using a basic numerical model. By varying the coolant flow rates, a hydrogen filling time of 12 min has been achieved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.