Abstract

The authors have presented an active control method of surge occurring in a centrifugal compressor, using the control valve which is provided separately from the flow control valve. The surge control valve is operated with the plenum pressure as the feedback signal. The experimental results using the proportional control and the delayed feedback control have shown that the present methods are effective for the active control of surge.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.