Abstract

The method of reducing automotive intake noise can be classified by passive and active control techniques. However, passive control has a limited effect of noise reduction at low frequency range (below 500 Hz) and is limited by the space of the engine room. However, active control can overcome these passive control limitations. The active control technique mostly uses the Least-Mean-Square (LMS) algorithm, because the LMS algorithm can easily obtain the complex transfer function in real-time, particularly when the Filtered-X LMS (FXLMS) algorithm is applied to an active noise control (ANC) system. However, the convergence performance of the LMS algorithm decreases significantly when the FXLMS algorithm is applied to the active control of intake noise under rapidly accelerating driving conditions. Therefore, in this study, the Co-FXLMS algorithm was proposed to improve the control performance of the FXLMS algorithm during rapid acceleration. The Co-FXLMS algorithm is realized by using an estimate of the cross correlation between the adaptation error and the filtered input signal to control the step size. The performance of the Co-FXLMS algorithm is presented in comparison with that of the FXLMS algorithm. Experimental results show that active noise control using Co-FXLMS is effective in reducing automotive intake noise during rapid acceleration.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call