Abstract
A human aorta from a female donor affected by Klippel-Trenaunay syndrome was retrieved during a surgery for organ donation for transplant. The aorta was preserved in refrigerated Belzer UW organ preservation solution and tested within a few hours for mechanical characterization with and without vascular smooth muscle activation. KCl and Noradrenaline were used as vasoactive agents in bubbled Krebs-Henseleit buffer solution at 37 °C. A quasi-static and a dynamic mechanical characterization of the full wall and the three individual layers were carried out for strips taken in longitudinal and circumferential directions. The full wall in the descending portion of the aorta underwent mechanical tests with and without smooth muscle activation. Results were compared to data obtained from healthy aortas and show a reduced stiffness of the full wall in circumferential direction. Also, a significant reduction of the response to vasoactive agents in circumferential direction was observed, while the longitudinal response was similar to healthy cases.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the Mechanical Behavior of Biomedical Materials
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.