Abstract

In preparation for the upcoming deuterium-tritium campaign at the JET tokamak, the ex-vessel fission chamber neutron diagnostics and the neutron activation system will be calibrated in absolute terms at 14MeV neutron energy, to a required accuracy of less than 10%. Two nominally identical DT neutron generators were chosen as the calibration sources, both of which were fully calibrated and characterized at the UK’s National Physical Laboratory. The neutron activation method was adopted as a complementary method for the purpose of determining the absolute value of the neutron yield from the neutron generators and to provide a means of cross check for the active detection methods being employed. The work being presented here shows the derivation of the neutron emission rate from the neutron generators based upon experimental activation foil measurements.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.