Abstract

The neutron flux generated by the CS-30 cyclotron at Mt Sinai Medical Center during routine internal target runs was characterized by employing various elements as neutron monitors. The characteristic (p, xn) nuclear reactions from internal targets bombarded by 26.5 MeV protons and the cyclotron inner wall bombarded by stray protons produce a neutron flux of approximately 2 × 10 9cm −2 s −1 at energies up to 22 MeV at a point immediately outside the cyclotron vacuum chamber. Samples exposed to neutron fluences up to 5 × 10 14 cm −2 were analyzed with a Ge(Li) detector. Although the detection limits are relatively high (i.e., Au−0.2 μg; In−1 μg; Na−50 μg), this mode of neutron activation analysis is ancillary to other irradiations and allows a large number of samples to be monitored. This approach may provide an alternative to a neutron generator for research activation applications.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.