Abstract

This study's objective was to clarify both experimentally and theoretically whether a vertical multistage tower aeration tank system is advantageous as compared with a completely mixed system, particularly with respect to purification efficiency, sludge settleability, and excess sludge production. In comparing the two systems: (1) purification efficiency in the multistage tower aeration system with partial fluid mixing with a large Peclet number was higher than in a corresponding completely mixed system for all applied organic loadings; (2) the multistage tower aeration system had some definite advantages with respect to sludge settleability and excess sludge production; (3) the activated sludge system's higher performance with partial fluid mixing was shown quantitatively with the axial dispersion model in conjunction with growth kinetics which involved rapid uptake such as biosorption and subsequent oxidative biodegradation processes of organic substances.