Abstract

The effect of calcium on activated sludge flocculation dynamics is investigated using a unique experimental technique. The technique allows on-line analysis of the size of activated sludge flocs during flocculation and provides valuable insight into the mechanisms of flocculation. Activated sludge samples were firstly sonicated for 3 minutes at 50 W and then stirred at 100 rpm. The floc size was subsequently measured on-line using a Malvern Mastersizer/E. For concentrations of calcium less than 4 meq/L no significant increase in final floc size was observed even though an increase in the initial rate of change of floc size could be seen. Addition of calcium greater than 4 meq/L resulted in a dramatic increase in floc size. Results from this investigation support the theory that cations are involved in flocculation through cationic bridging, and will be used in ongoing investigations to model the flocculation process.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.