Abstract

To improve myocardial perfusion magnetic resonance imaging (MRI) by reconstructing undersampled radial data with a spatiotemporal constrained reconstruction method (STCR). The STCR method jointly reconstructs all of the time-frames for each slice. In 7 subjects at rest, on a 3-T scanner, the method was compared with a conventional (GRAPPA) Cartesian approach. Increased slice coverage was obtained, as compared with Cartesian acquisitions. On average, 10 slices were obtained per heartbeat for radial acquisitions (8 of which are suitable for visual analysis with the remaining 2 slices, in theory, usable for quantitative purposes), whereas 4 slices were obtained for the conventional Cartesian acquisitions. The new method was robust to interframe motion, unlike using Cartesian undersampling and STCR. STCR produced images with an image quality rating (1 for best and 5 for worst) of 1.7 +/- 0.5; the Cartesian images were rated 2.6 +/- 0.4 (P = 0.0006). A mean improvement of 44 (+/-17) in signal-to-noise (SNR) ratio and 46 (+22) in contrast-to-noise ratio (CNR) was observed for STCR. The new radial data acquisition and reconstruction scheme for dynamic myocardial perfusion imaging is a promising approach for obtaining significantly higher coverage and improved SNR ratios. Further testing of this approach is warranted during vasodilation in patients with coronary artery disease.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.