Abstract

Acoustically generated flowfields in flexural plate wave sensors filled with a Newtonian liquid (water) are considered. A computational model based on compressible flow is developed for the sensor with a moving wall for pumping and mixing applications in microchannels. For the compressible flow formulation, an isothermal equation of state for water is employed. The velocity and pressure profiles for different parameters including flexural wall frequency, channel height, amplitude of the wave and wave length are investigated for four microchannel height/length geometries. It is found that the flowfield becomes pseudo-steady after sufficient number of flexural cycles. Both instantaneous and time averaged results show that an evanescent wave is generated in the microchannel. The predicted flows generated by the FPWs are compared with results available in the literature. The proposed device can be exploited to integrate micropumps with complex microfluidic chips improving the portability of micro-total-analysis systems.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.