Abstract

We report a robust and very precise method of measuring temperature using ultrasonic waves. Solid stainless steel waveguides are used to provide well-defined and stable ultrasonic wave propagation paths. Ultrasonic wave velocity is strongly temperature dependent. The arrival times of the ultrasonic wavepackets along a waveguide are used to infer the average temperature of the waveguide. Our ultrasonic temperature measurements exhibit a high precision (i.e. ±0.015 °C) that is more than two times better than the quoted accuracy of 1/10 DIN resistance temperature detectors (RTDs). The responsiveness of the waveguides was also investigated. While ultrasonic measurements can be made at very high frequencies, the responsiveness is limited by the heat transfer into the active sensing area. The waveguides make it easy to customise the dimension of the active sensing area and a shorter response time than those of RTDs has been demonstrated. The technique presented in this paper is a robust and cost effective alternative to other contact temperature measurements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.