Abstract

The classical two-duct Herschel–Quincke tube is modified by means of an additional pipe connecting both paths. A transfer matrix is obtained for a mesh system with five arbitrary branches and then particularized to the proposed scheme. Experimental attenuation measurements were performed on several prototypes, and the results compared favourably with predictions from the previous theoretical development. Finally, transmission loss contour plots were used to study the influence of the connecting pipe on the resonance frequencies. The results confirm the nontrivial character of the influence observed, and simple relationships are obtained for the general trends.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.