Abstract
It is held as fact that Permanent Magnet (PM) brushless motors are less noisy than Switched Reluctance (SR) motors, and many methods have been published to reduce the noise of SR drives. This paper provides a systematic experimental comparison of both drives, and of proposed noise- mitigation strategies, in the context of a specific mass-market application: Automotive Electro Mechanical Brakes (EMB). The two motors were designed to fit into the same envelope and to produce similar dynamic performance for the brake system. Sound pressure levels produced by the two motors at key torque-speed points were measured through dynamometer tests under identical conditions. The influence of the hysteresis current and PWM control methods on the acoustic noise was also studied. The acoustic noise was then measured with the EMB systems assembled with the PM and SR motors. Though the measured acoustic noise of the SR motor with dynamometer tests was higher compared to that of the PM motor, the acoustic noise levels of the two EMB systems were found to be similar with only a slight advantage to the PM based system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.