Abstract

An understanding of the acoustic cavitation threshold is essential for minimizing cavitation bio-effects in diagnostic ultrasound and for controlling cavitation-mediated tissue ablation in focused ultrasound procedures. The homogeneous cavitation threshold is an intrinsic material property of recognized importance to biomedical ultrasound as well as a variety of other applications requiring cavitation control. However, measurements of the acoustic cavitation threshold in water differ from those predicted by classic nucleation theories. This persistent discrepancy is explained by combining recently developed methods for acoustically nucleating single bubbles at threshold with numerical modeling to obtain a nucleus size distribution consistent with first-principles estimates for ion-stabilized nuclei. We identify acoustic cavitation at threshold as a reproducible subtype of heterogeneous cavitation with a characteristic nucleus size distribution. Knowledge of the nucleus size distribution could inspire new approaches to achieving cavitation control in water, tissue and a variety of other media.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call