Abstract

AE technique was applied to the structural strength tests of the ablative composite liner bonded on steel nozzle to figure out the unexpected problem that happened during the flight test. Two different kinds of specimen, which were specimens with some initial crack and without initial crack each, were used for the test. AE test methodology and parameters were investigated to assess the damage of them. NDT using X-ray technique was performed to improve the test reliability before and after each test. The study revealed that AE technique is a good method to evaluate damage on this kind of specimen with better accuracy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.